AMPRO 2000 Gas Analyzer
Powerful, Handheld Combustion / Emission Analyser for industrial combustion and emission measurements.
- Low cost of ownership
 - Extremely user friendly
 - +4 years O2 sensor Life Experience
 - Active CO sensor protection
 
Simultaneous measurements of up to 7 gas components!
- 02, CO, C02, NO, NO2, SO2, CO-high, & CO-very high,
- Up to 5 electrochemical sensors, plus C02/Hydrocarbon NDIR bench is possible!
 - Low CO, NO and NO2 ranges are available
 
 - Emission calculations such as mass flow, calculated or True NO(x), plus O2 referencing to user defined values
 - Gas temperature measurement up to 2,012F (use stainless steel up to 1,200F, use Incomel tubes up to 2,012F)
 - Large condensate separator with PTFE (Teflon) coated filter
 - Air purging pump for CO-sensor protection
 - Internal data storage for up to 16,000 measurements!
 - High energy Li-ion battery provides up to 15 hours operation
 - Large color graphic, backlit display with zoom function
 - Customizable screen settings
 - Durable and dirt resistant keypad
 - IR interface for external printer (printer is opional)
 - Integrated so card reader for additional memory and easy data handling
 
Also measures...
- Combustion air temperature
 - Stack gas temperature
 - Stack draft
 - Differential pressure
 - Differential temperature
 
And calculates...
- CO2
 - CO/CO2 ratio
 - Dew point
 - Excess air and air ratio (Lambda)
 - Combustion efficacy
 - Heat losses
 
Specifications:
| Measured components | Measuring Ranges | Resolution | T90 | Accuracy | |
| O2 | Oxygen | 0 … 21.0 Vol-%
 
 OPTIONAL (25%)  | 
0.1 % | < 20 sec. | ± 0.2 Vol-% abs. | 
| CO | Carbon monoxide | 0 … 4,000 ppm
 
 overload 20,000ppm *1  | 
1 ppm | < 40 sec. | ± 10 ppm or 5 % reading < 4,000 ppm / 10 % reading > 4,000 ppm | 
| CO low | Carbon monoxide | 0 … 500 ppm
 
 *2  | 
0.1 ppm | < 40 sec. | ± 2.0 ppm or 5 % reading | 
| CO high | Carbon monoxide | 0 … 4 %
 
 overload 10 % *1  | 
1 ppm | < 40 sec. | ± 0.02% or 5 % reading < 0.4% / 10 % reading > 0.4% | 
| NO | Nitric oxide | 0 … 1,000 ppm
 
 overload 5,000ppm *1  | 
1 ppm | < 30 sec. | ± 5.0 ppm or 5 % reading < 1,000 ppm / 10 % reading > 1,000 ppm | 
| NO low | Nitric oxide | 0 … 300 ppm
 
 *2  | 
0.1 ppm | < 30 sec. | ± 2.0 ppm or 5 % reading | 
| NO2 | Nitrogen dioxide | 0 … 200 ppm
 
 overload 1,000ppm *1  | 
1 ppm | < 40 sec. | ± 5 ppm or 5 % reading < 200 ppm / 10 % reading > 200 ppm | 
| NO2 low | Nitrogen dioxide | 0 … 100 ppm
 
 *2  | 
0.1 ppm | < 40 sec. | ± 2.0 ppm or 5 % reading | 
| SO2 | Sulfur dioxide | 0 … 2,000 ppm
 
 overload 5,000ppm *1  | 
1 ppm | < 40 sec. | ± 10 ppm or 5 % reading < 2,000 ppm / 10 % reading > 2,000 ppm | 
| CO2 *3 | Carbon dioxide | 0 … 40% | 0.01 % | < 35 sec. | ± 0.3 % or 3% reading | 
| CO2  *4
 
 CxHy  | 
Carbon dioxide
 
 Hydrocarbons  | 
0 … 40%
 
 100 … 40,000 ppm  | 
0.01 %
 
 10 ppm  | 
< 35 sec.
 
 < 35 sec.  | 
± 0.3 %  or 3% reading
 
 ± 400 ppm or 5% reading  | 
| *1 – overload ranges are recommended only for short time measurements
 
 *2 – are not separate sensors; selected sensors are used with special calibration *3 – Single NDIR *4 – DUAL NDIR  | 
|||||
| Other measured components | Measuring Ranges | Accuracy | 
| Stack / Flue gas temperature | 32 … 1,472°F (0 … 800°C) with stainless steel
 
 32 … 2,012°F (0 … 1100°C) with Inconel  | 
± 4°F … < 392°F / 1 % reading > 392°F
 
 ± 4°F … < 392°F / 1 % reading > 392°F  | 
| Primary air / Ambient air temperature | 32 … 212°F (0 … 100 °C) | ± 2°F | 
| Differential temperature | Up to 2,012°F (0 … 1100°C)
 
 (with suitable material of sampling tube)  | 
± 4°F … < 392°F / 1 % reading > 392°F | 
| Stack draft | +/- 40 inH2O (100hPa) | ± 0.01 inH2O or 1% reading | 
| Differential pressure | +/- 120 inH2O (300hPa) | ± 0.01 inH2O or 1% reading | 
| Gas flow velocity measurement | 1 … 40 m/s (using Pitot tube) | 
| Calculated values | Range | Calculated values | Range | 
| Carbon dioxide | 0 … CO2 max. | Air Ratio (Lambda) | 1 … 9.99 | 
| Heat losses qA | 0 … 99.9 % | Excess Air | 0 … 99.9 | 
| Efficiency | 0 … 100 % / 120 % | CO/CO2 ratio | 0 … 10 | 
| GENERAL SPECIFICATIONS | |
| Max suction range gas pump | 60 inH2O (150 hPa) | 
| Typical gas flow | 16 gal/h (60 l/h) | 
| Internal memory | 16,000 data sets | 
| Data transmission | via USB, SD Card or Bluetooth | 
| Interfaces | SD card reader, USB, IR, Bluetooth | 
| Display | 3.5″ TFT color display | 
| Operation temperature | 41°F …. 113°F (5 … 45°C) max. 95 % RH, none condensing | 
| Storage temperature | -4°F ….. 122°F (-20°C … 50°C) | 
| Ambient conditions | not in aggressive, corrosive or high dust ambience, not for use in hazardous areas | 
| Battery operated | Lithium-Ion battery, 20 h operation time | 
| Grid power supply | 100 – 240 V AC / 50 … 60 Hz 1.2A | 
| Protection class | IP 30 | 
| Weight | approx. 2.2 lbs. (with 7 sensors) | 
| Dimensions | ( W x H x D) 4.3” x 8.8” x 2.04” | 
| TÜV approval | ByRgG 280 acc. 1. BImSchV and EN 50379 | 